蔣莎 譚林華 張慶
摘 要:文章基于變壓器在開關(guān)電源的應(yīng)用討論了變壓器的設(shè)計方法,給出了變壓器主要參數(shù)的詳細(xì)設(shè)計方法,包括參數(shù)計算、磁芯選擇、線圈繞制和損耗計算等。根據(jù)設(shè)計步驟,以全橋逆變-全橋整流DC/DC變換器為例,設(shè)計了一臺7kW高頻變壓器。
關(guān)鍵詞:高頻;變壓器;設(shè)計
中圖分類號:TM433 文獻(xiàn)標(biāo)志碼:A 文章編號:2095-2945(2018)28-0099-03
Abstract: This paper discusses the design method of transformer based on the application of transformer in switching power supply, and gives the detailed design method of main parameters of transformer, including parameter calculation, core selection, coil winding and loss calculation. According to the design procedure, a full bridge inverter to full bridge rectifier DC/DC converter is taken as an example, and a 7kW high frequency transformer is designed.
Keywords: high frequency; transformer; design
引言
隨著技術(shù)的發(fā)展,開關(guān)電源中的其它器件集成度越來越高。變壓器卻往往需要根據(jù)具體的應(yīng)用來定制所需的產(chǎn)品。其性能的優(yōu)劣直接影響到開關(guān)電源的可靠性和穩(wěn)定性。[1]因此,了解和掌握變壓器的設(shè)計對開關(guān)電源的設(shè)計具有重要意義。
1 高頻變壓器運用條件
3 結(jié)束語
本文以全橋逆變-全橋整流拓?fù)潆娐窞槔懻摿烁哳l變壓器的設(shè)計方法,給出了詳細(xì)的設(shè)計計算步驟。為開關(guān)電源領(lǐng)域高頻變壓器設(shè)計提供了一種有效的方法。
參考文獻(xiàn):
[1]唐海燕,李建泉.DC/DC變換器中25kW高頻功率變壓器的設(shè)計[J].大功率變流技術(shù),2010,2:26-30.
[2]周潔敏,趙修科,陶思鈺.開關(guān)電源磁性元件理論及設(shè)計[M].北京:北京航空航天大學(xué)出版社,2014:191,219,220.