      A membrane separation technique for optimizing sample preparation of MALDI-TOF MSdetection

      2019-02-15 02:27:34ZengnanWuNingXuWeiweiLiJinMingLin
      Chinese Chemical Letters 2019年1期

      Zengnan Wu,Ning Xu,Weiwei Li,Jin-Ming Lin,*

      a State Key Laboratory of Chemical Resource Engineering,Beijing University of Chemical Technology,Beijing 100029,China

      b Beijing Key Laboratory of Microanalytical Methods and Instrumentation,Department of Chemistry,Tsinghua University,Beijing 100084,China

      Key words:MALDI-MS Membrane separation Nanomaterial Mastoparan Insulin Cytochrome C

      ABSTRACT The performance of matrix-assisted laser desorption/ionization time of fl ight mass spectrometry(MALDI-TOF-MS)is frequently compromised by the high limited of detection,heterogeneous distribution of matrix and analyte deposits and time-consuming drying time during the conventional drop drying procedure.Here,we describe a method based on membrane separation technology to assist in the drying of nanomaterials to rapidly make homogeneous sample spots and to enhance the mass signal.We demonstrate that the sample can be dried evenly in a few secondsand MSsignal can be greatly optimized by using membrane separation technology.Enrichment with nanomaterials greatly enhances analyte signal strength while membrane separation method avoids the time-consuming requirements of searching for “sweet spots”.

      Matrix-assisted laser desorption/ionization mass spectrometry(MALDI-MS),fi rst introduced in the late 1980s as a soft ionization technique[1,2],provides a simple,high throughput analytical method for high molecular weight species and has been used extensively in various biochemical study[3,4].The obvious advantage of MALDI-MS is its tolerant to buffer,salt,and other additives in the sample,and greatly reduces analysis time.Organic matrix is commonly used to promote analyte ionization,but more recent efforts have been devoted to fi nding alternative matrices to overcome some of the limitations associated with organic matrices,such as low m/z interference and point-to-point signal heterogeneity.Nanomaterials including carbon nanotube[5],graphene[6],gold[7],silver,silicon[8],iron oxide,titanium dioxide[9]and zinc oxide nanoparticles have been w idely investigated as an alternative matrix for MALDI-MS as a w ay of minimizing low m/z interference.And nanomaterial have also been used as pre-enrichment materials for concentrating analytes to enhance MALDI-MSsignals[10].

      Many studies have explored how to dry nanoparticles uniformly on the surface as a means of improving signal homogeneity in traditional dried droplet approach to MALDI samples preparation.It is know n that nanomaterials w ill accumulate a ring spot w hen depositing onto a surface via a phenomenon know n as the “coffee ring”effect[11].The formation of it depends on many variables,including nanoparticle size,chemical surface[12]and temperature[13].This coffee-ring effect occurs as suspended particles and solute are carried to the outer edge of the spot due to capillary fl ow in the drying sample.These fl ow s,know n as Marangoni fl ow s,are typically the cause of the heterogeneity observed in traditional MALDI spots,and several creative approaches[14]have been explored to surmount this obstacle.

      Membrane separation method is characterized by a fast solidliquid separation[15]method with its fi lter principle[16]being w idely studied.The uniform distribution of contaminants on the membrane surface factors into the fi ltration performance.

      Here,we describe a method of depositing nanoparticles through membrane separation method using disposable porous membrane as mass plate to improve sample spot uniformity(Fig.1).Carbon nanotubes(CNTs)[17]are highly surface area material with negative zeta potential and easy to capture oppositely charge analytes through electrostatic interaction.Therefore,it may also serve as a marvelous pre-enrichment material[18]for capturing protein molecules.We found that the nanoparticles can be uniformly and rapidly deposited on the surface of porous mass plate through the membrane separation process.Due to the enrichment of the nanoparticles and the uniformity of the sample spots,the strength and uniformity of the analytical signal are improved.

      Fig.1.Schematic illustration of MALDIMSdetection based on the combination of membrane separation technology and nanomaterial applications to rapid detection of biomolecules.

      In all experiment:Polycarbonate fi lter membrane with a nominal pore size of 0.8 m m was bought from Merck Millipore(Germany).CNTs were purchased from Aladdin(Shanghai,China).Sodium hydroxide,citric acid(CA),ammonium citrate and sodium chloride were obtained from Beijing Chemical Reagent Co.(Beijing,China).Peptides of KCRKA and KCKRTR were obtained from Bank peptide(Hefei,China).Cytochrome C was purchased from Harveybio Co.(Beijing,China).Insuli was purchased from Solarbio Co.(Beijing,China).The MALDI matrix a-cyano-4-hydroxycinnamic acid(CHCA),3,5-dimethoxy-4-hydroxycinn amic acid(SA)and 2,5-dihydroxybenzoic acid were purchased from Sigma-Aldrich(U.S.A.).Tri fl uoroacetic acid was purchased from Sigma-Aldrich(U.S.A.).Puri fied w ater was produced by Wahaha Group(Hangzhou,China).All chemicals were purchased at the highest purity grade available and were used without further puri fi cation.CNTs suspension according to previously reported protocol[17]with a slight modification.In brief,pristine CNTs(3 mg)were dispersed in 1 m L CA aqueous solution(100 mmol/L)by ultrasonication for 5 min to disperse the CNTs well.Each CHCA(10 mg/m L),SA(10 mg/m L)and DHB(10 mg/m L)matrix was dissolved in a mixture of ACN and 0.1%aqueous TFA(1/2,v/v).All the authentic standard compounds were weighed accurately and then dissolves in deionized w ater and diluted with proper solvents by different ratios for proper concentrations.

      Microscopic image of the sample spot was recorded using a Spinning Disk(Perkin Elmer,U.S.A.).Porous membrane was modified through ion sputtering instrument(Hitachi,Japan).MALDI-TOF-MS analysis was performed on CLIN-TOF-II instrument(Beijing Bioyong,China).Each mass spectrometer uses a 337 nm nitrogen laser for desorption.The acceleration voltage was 20 k V,and the vacuum pressure in the ion source was(3-5)?10?6Torr.Data were acquired in a positive linear mode and evaluated by using the mass spectrometry softw are(Shimadzu Biotech.,Japan).

      In the search for the disposable and porous as required for separation and MALDI-TOF-MSanalysis,the modified commercial polycarbonate fi lter membrane turned out to be our choice.The form of polycarbonate fi lter membrane was given by etching on the surface of a polycarbonate fi lm which features smooth and neat surface with precisely uniform pore.Through ion sputtering,a 5 nm-thick gold fi lm was deposited onas required for separation and MALDI-TOF-MS analysis,the modified commercial polycarbonate fi lter membrane turned out to be our choice.The form of polycarbonate fi lter membrane wasgiven by etching on the surface of a polycarbonate fi lm which features smooth and neat surface with precisely uniform pore.Through ion sputtering,a 5 nm-thick gold fi lm was deposited on the fi lter to add better electrical conductivity to the surface.We applied gold-plated fi lter membrane as a disposable MALDI plate and sample preparation was done quickly by solid-liquid separation.

      As current MALDI-TOF-MS detection mainly relies on reusing metal mass plate,its manual cleaning act as not only timeconsuming work,but also a high residual risk.We apply goldplated fi lter membrane as a disposable MALDIplate w here a good number of 800 nm circular pores evenly distributed on its surface.For this reason,particlesover 800 nm w ill be trapped on itssurface during the separation.Then is further detected by MALDI-TOF-MS analysis.Comparatively,the porous plate is a cheap,clean and stable disposable mass plate that makes rapid sample preparation and accurate mass spectrometry detection available,which could provide a strong support for rapid analysis.

      As the results show n in Fig.2,during the course of conventional drying,the contact line is pinned and cannot receded,and solvent lost by evaporation at the droplet's edge must be replaced by solvent draw n from the center of the droplet.So the drop diameter remains constant and the contact angle decreases during evaporation.The fl ow that brings fluid from the center to the edge of the droplet also carries solute,which is the fi nal formation of cyclic deposit.In contrast,by a w ay of direct solid-liquid separation,the mixture is allowed to pass through the porous target plate vertically under the pressure difference.

      Nanomaterials with adsorption of target sample are trapped by a porous plate,solvent is rapidly separated from the sample under pressure and drive through the target.This process takes only a few seconds.Figs.2A–D show that the conventionally dried sample spots consisting of rather large isolated crystallization that are sometimes partially freely distributed.By contrast,w hen we dried the sample through the membrane separation using a porous membrane,we w ould get a uniform sample spot(Fig.2E).

      For testifying the increase of signal intensity,we compared the sample MALDIspectra of dried spots obtained at arbitrary location from membrane separation samples(blue curves)and natural dried samples(red curves).The observed increase in signal intensity was con fi rmed upon recording actual MALDI spectra.Fig.3 illustrates the signal intensity of peptides before and after using CNTs as adsorbent to enrich peptides.As it clearly seen,after enrichment the signal from the mastoparan,insulin and cytochrome Csignals were significantly enhanced.We employed low concentration of cytochrome Ctryptic digest products to demonstrate the feasibility of this application.Fig.4 presents that our method enhances the signal of cytochrome C tryptic digest products.Fig.4A presents the MALDI mass spectrum of cytochrome C digest product prior to enrichment.Only peaks at m/z 1168.7321 and 1633.2276 are observed,while Fig.4Bpresents that more digest products peaks can be obtained and the intensity of the signal increased.

      Fig.2.Sample spots obtained by traditional drying method of different matrix:CHCA(A),SA(B),2,5-DHB,CNTs(D),and by membrane separation method(E).

      Fig.3.MALDImass spectra for various samples before(red)and after enrichment(blue).(A)mastoparan,(B)insulin,and(C)cytochrome C.

      Fig.4.MALDImass spectra of cytochrome Ctryptic digest product.CHCA(A)and CNTs(B)were used as matrix,respectively.The mass peak observed of 1168.73,1433.65 and 1633.22 were peptides of TGPNLHGLFGR,HKTGPNLHGLFGR and IFVQKCAQCHTVEK.

      Fig.5.Typical pro fi le of the signal variation of peptide of KCRKA(100 pmol/L)for 7 individual spot through(A)conventional drop drying process and( B)membrane separation method.

      To characterize the ef fi ciency and uniformity of MALDI-MS preparation techniques,we recorded the signal variation of insulin for eight precise sites on dried sample spots.Consistent with the non-uniform distribution of the samples seen in the optical images,the signal distribution of the sample spots of the conventionally dried samples is very uneven and requires the search for “sweet spots”.And as expected,Fig.5 con fi rms that membrane separation improves the signal strength and uniformity drastically without a time-consuming search for a sweet spot.Wherever the laser is directed onto the uniform sample spot,intense MALDI spectra can be obtained.We collected MALDI images of peptide of KCRKA dried by membrane separation and conventional method.As it is seen from Fig.5 that membrane separation dried samples are much more homogeneousthan in the case of conventional dried samples.Comparison to the conventional dried samples show s that the mass peak obtained is the same as the one dried by conventional method in chemically identical aspect.As expected,based on the purely physical character of the method,membrane separation method therefore does not generate additional interfering peaks,unlike other enhancement methods that require additives.

      In conclusion,we describe a novel sample preparation method based on the combination of membrane separation technology and nanomaterial applications to optimize MALDI detection of biomolecules.For peptides and protein biomolecules,the enhanced signals and improved signal homogeneity have been demonstrated.The method is convenient,fast,effective,and has great potential for practical application in the future.

      Acknow ledgm ent

      This work was supported by the National Natural Science Foundation of China(Nos.21435002,21621003).