• 
    

    
    

      99热精品在线国产_美女午夜性视频免费_国产精品国产高清国产av_av欧美777_自拍偷自拍亚洲精品老妇_亚洲熟女精品中文字幕_www日本黄色视频网_国产精品野战在线观看 ?

      Numerical analysis of shear resistance of concrete filled double-steel-plate composite walls with shear stud connectors

      2021-03-07 12:14:40,,

      , ,

      College of Civil and Transportation Engineering, Hohai University, Nanjing 210098,P. R. China)

      Abstract: The concrete filled double steel plate composite wall (CFDSPCW) with shear stud connectors is a new type of construction component for high-rise buildings that resist lateral force. In this paper, the in-plane shear resistance of CFDSPCWs is studied with nonlinear finite element analysis using ANSYS. To this end, some assumptions were made to simplify the numerical model. Based on the experimental results and the formula of shear-slip of stud connectors in the literature, a constitutive relationship explaining the shear-slip of shear stud connectors is proposed using curve fitting. Then, the finite element model of the experimental CFDSPCW is established and validated through experimental results. Thereafter, the study presents the effects of key parameters including the space of stud connectors, the thickness of both the steel plate and concrete core, the concrete strength, and the span-depth ratio of walls on the shear resistance of CFDSPCWs. The results indicate that the thickness of both the steel plate and the concrete core, and the strength of concrete are the most critical factors affecting the shear resistance of CFDSPCWs, and the spacing of stud connectors affects the failure mode of CFDSPCWs.

      Keywords:composite wall; shear connectors; shear resistance; numerical analysis; composite structures

      1 Introduction

      As the lateral load is considered to be the dominant factor in the structural design of a high-rise building, the lateral force-resisting system is the most important part of a high-rise building[1]. Concrete filled double steel plate composite walls (CFDSPCWs) with shear stud connectors are proposed as a new type of shear wall structure[2-3]. The steel-concrete-steel (SCS) wall developed by the Corus Company[4]consists of two steel plates and a concrete core. The SCS wall integrates the advantages of steel and concrete and has a high shear resistance and lateral stiffness. The SCS wall is constructed using shear connector rods attached to both steel plates through a high-speed rotational friction weld process. However, the interaction between the concrete and steel plates is too complicated to be used in a high-rise building. In order to simplify the interaction of the steel plates and the concrete core of the composite shear wall, the CFDSPCW with shear stud connectors was developed by Nie et al., and is suitable for high-rise buildings[5].

      At present, there are dozens of buildings with CFDSPCW structures used as the lateral force-resisting components worldwide, which are mainly distributed in high seismic intensity regions such as North America and Japan. There are some domestic buildings using this CFDSPCW structure such as the main structure of an Avalokitesvara statue[5], the tube structure of the Yancheng TV tower[6], and the main structure of the Guangzhou East Tower[7], which indicates that the use of this type of structure is still in the early stage in China.

      Due to its good mechanical performance, convenient construction and high reliability, the stud connector has become the most widely used shear connector and is also used in the CFDSPCW structure studied for this paper. In addition, to improve the integrity of the composite shear wall and strengthen the lateral restraint of the internal concrete, stud connectors are welded onto each steel plate. Moy et al.[8]conducted a push-out test of stud connectors and studied their shear stiffness and strength. Nie et al.[7, 9]experimentally investigated the seismic performance of CFDSPCWs with stud connectors under different axial compression ratios, shear span to effective depth ratios and intervals between stud connectors. Their results showed that the CFDSPCW had good ductility and energy dissipation capacity, and thus could potentially be applied in high-rise buildings.

      There are also studies of the shear resistance of steel-concrete composite walls[10-15]. Wei et al.[10]carried out numerical analyses and theoretical analyses on CFDSPCWs using friction welded transverse bars as shear connectors and proposed a formula to calculate the shear capacity of the corresponding CFDSPCWs. Zhu et al.[11]numerically investigated the shear behavior of CFDSPCWs with plate stiffeners and shear studs as combined shear connectors, and then proposed an analytical solution for shear capacity based on the diagonal compression model of shear mechanism that considered concrete damage. Guo et al.[12]proposed a strut and tie model to calculate the shear capacity of CFDSPCWs with confined boundary elements under cyclic loading tests. The model consists of distributed diagonal compression struts made of concrete and the diagonal tension tes contributed by face steel plates. Moreover, the ties are perpendicular to the struts and the contribution of the walls’ axial compression on the shear resistance is considered based on curve-fitting. Ji et al.[13]conducted cyclic tests on five steel-concrete composite shear walls, in which steel plates were encased in concrete or put on surface with a concrete core. The test data, together with that of 46 steel-concrete shear walls, were used to evaluate the formulae of shear capacity adopted in different codes. Xiong et al.[14]experimentally and numerically investigated three CFDSPCWs under cyclic loading, and proposed a formula for calculating shear capacity of CFDSPCWs through curve fitting on top of the shear capacity formula of reinforced concrete shear wall. Zhang et al.[15]derived the shear capacity and corresponding shear strain of CFDSPCWs used in nuclear engineering at the elastic, concrete cracking, steel plate yielding and final stages based on the assumption of perfect composite effects between the concrete and steel plates, in which the ultimate capacity was derived based on the cross-diagonal strut model. In summary, the systematic analysis of the shear resistance and behavior of CFDSPCWs with shear stud connectors used in high-rise buildings is still rare in the literature. It is not clear whether the current shear capacity formulae apply to CFDSPCWs with only shear stud connectors that are used in high-rise buildings. In addition, previous numerical studies and theoretical analyses presume that there is a perfect composite effect between the concrete and steel plates. However, in practice, a slip between the shear studs and the concrete core could occur.

      In this paper, the shear resistance of CFDSPCWs with shear stud connectors is numerically studied using the ANSYS finite element analysis software. The numerical models consider the shear-slip effect between the concrete and studs, and the contact of steel plates and concrete core. The numerical model was initially validated by previous experimental results and then used to investigate the effects of key parameters on the shear resistance of CFDSPCWs. The key parameters include the interval between the shear stud connectors, the thicknesses of steel plates and concrete plates, the strength of the concrete, and the height-width ratio of the walls.

      2 Numerical modeling and validation

      2.1 Simplification of the model

      In order to focus on the shear resistance of a CFDSPCW, we have made some assumptions to develop a simplified model of a CFDSPCW, as shown in Fig.1. These assumptions are as follows[16]: 1) Between the CFDSPCW and the surrounding frame beams, as well as the columns, the nodes at the four corners are pin connections, and the effect on the lateral resistance of frame bending is ignored; 2) the flexural stiffness of the frame beams and columns is adequate to provide sufficient anchorage capacity for a CFDSPCW; and 3) the axial deformations of both the frame beams and the columns are ignored. Since the entire beams are connected to the walls, the axial deformation of frame beams can be ignored. To avoid the effect of the overturning moment of columns on the shear resistance of a CFDSPCW, the axial deformation of frame columns is ignored as well.

      As shown in Fig.1,ADandBCrepresent the frame columns, whileABandDCdenote the frame beams. The section dimensions of the frame columns and beams are H300 mm×300 mm×10 mm×15 mm, in which the section is 300 mm in width and in depth and the thickness of web and flange is 10 mm and 15 mm, respectively. The yield strength of all the steel used in the CFDSPCWs was 235 MPa. The geometric and material properties of the CFDSPCW specimens used for the parametric studies are listed in Table 1.HandLrepresent the height and the span (or width) of the CFDSPCW specimens, respectively;was the height-width ratio (H/L) of the CFDSPCW,dswas the interval between the shear stud connectors,tsandtcwere the thickness of each face steel plate and concrete core, respectively; andfcukwas the strength of the concrete.

      Table 1 Geometric and material properties of CFDSPCW specimens

      2.2 Description of finite element model

      The finite element (FE) model of a CFDSPCW structure is shown in Fig.2. All the elements used are part of the ANSYS software. The concrete is modeled using the solid element SOLID65. The constitutive model of the concrete in theCodeforConcreteStructureDesign(GB 50010-2010) is used in this paper. Steel plates were modeled using the SHELL181 element. The ideal elastic-plastic model was used for the constitutive model of steel plates. The SOLID45 element was used for the frame beams and columns.

      Fig.2 Finite element model of a CFDSPCW

      The formula for the shear-slip of shear stud connectors[17]is given by the Eq. (1).

      V=Vu(1-e-ns)m

      (1)

      whereVuis the ultimate shear capacity of the shear stud connectors,Sis the relative slip of shear stud connectors and concrete;mandnrepresent the curve-fitted parameters, which are related to the dimensions of the shear wall. Based on the given formula for the shear-slip of shear connectors[17]and the push-out tests of stud shear connectors[18-19], the shear-slip relationship parameters of stud shear connectors can be curve-fitted.

      The nonlinear spring element COMBIN39 is used for modeling the shear stud connectors[20]. The spring stiffness is calculated by the nonlinear shear-slip relationship given by Eq. (1). A contact element is used for the interaction between the concrete plate and the steel plate. CONTA173 is used for the internal surface of the steel plates, and TARGE170 is used for the external surface of the concrete plate; these elements are paired to represent the interface between the steel plate and the concrete plate. The contact surfaces are assumed to be smooth and without the inter-penetration of concrete and steel. The concrete plate and the steel plate transfer normal pressure to each other, but the normal tensile force is not considered.

      The lateral load is applied with displacement-control. The largest lateral displacement is limited to 1/50 times that of the inter-story drift angle. At the same time, the initial elastic lateral stiffnessK0is set as the slope at the origin point of the load-displacement curve.

      2.3 Finite element analysis

      The finite element analysis consisted of three steps. First, an FE model of a CFDSPCW without any initial geometrical imperfections was constructed and applied with displacement constraints.

      Second, because of the effects of processing, transportation, installation and other factors, steel plates in practical engineering applications will inevitably have some initial deformation and initial defect. The unit forceFwas applied in the FE model of the CFDSPCW. From the buckling eigenvalue analysis, the first buckling mode of the CFDSPCW was obtained and used for generating the initial geometrical imperfections, which should be considered to demonstrate the out-of-plane buckling and the geometric nonlinearity of the steel plates. According to the requirement of flatness of a concrete plate in a steel-concrete composite shear wall structure, the maximum amplitude of the initial defects of the steel plate isLmax/1 000 (Lmaxis the length of the longer edge of a steel plate)[21].

      Third, an FE model of a CFDSPCW with its initial geometrical imperfections was constructed. The displacement constraints and the lateral displacement were applied to the FE model considering any large deformations, material nonlinearity and/or geometric nonlinearity. To calculate the ultimate shear capacity of the CFDSPCW, the equilibrium path of the load and displacement was traced using the arc-length method.

      2.4 Validation of numerical model

      A quasi-static seismic experiment of a CFDSPCW structure with stud connections was reported in the literature [9]. The dimensions of the composite shear wall in the test are shown in Fig.3. The section dimension of the two concrete-filled steel tubular columns (including the steel tubes) was 100 mm×120 mm. The sectional dimensions of the composite wall (including the steel plates) was 600 mm×90 mm. The concrete plate and the steel plates were connected with stud connectors at an interval of 100 mm. The thicknesses of the steel plates and steel tubes were 3 mm. The yield strength of the steel is 360 MPa. The cubic compressive strength of concrete was 27.5 MPa.

      Fig.3 Dimensions of the test

      To validate the FE model of the CFDSPCW structure, the results of numerical analysis were compared with the experimental results as shown in Fig.4; this shows that the numerical results are almost the same as the experimental results at the linear elastic stage. With the increasing of the displacement, the load-displacement curve of the numerical analysis deviated from the experimental curve; but both of the curves show the same trend and are very close to each other in terms of ultimate shear resistance. The experimental and numerical resistance was 1 015.5 kN and 997.6 kN, respectively, and the latter is approximately 98% of the former. Therefore, this FE model of the CFDSPCW structure was extended for use in parametric studies.

      Fig.4 Comparison of the load-displacement

      3 Shear mechanism of composite walls

      Based on the experimental and numerical results of the CFDSPCW under shear with different shear connectors, the shear mechanisms were identified and mechanical-based formulae were derived to calculate the ultimate shear capacity. Basically, the proposed formulae are all based on the cross-diagonal strut and tie model, i.e., the concrete forming diagonal compression struts between cracks and steel plates contributing diagonal tension ties. Moreover, the concrete cracked in the diagonal direction, and the diagonal tension yielding was perpendicular to the cracks[10-15]. As a result, the shear capacity was simply contributed by steel tension and concrete compression. The major difference is the formula of concrete compression in the following four models. To determine the critical parameters related to the shear capacity, and to compare the numerical results with the analytical results, four formulae are listed as follows:

      1)The contribution of the concrete core to the shear bearing capacity of CFDSPCWs is considered in two ways: the nominal shear acting at the section along the span direction, and the diagonal compression strut[10]. This can be written as

      (2)

      2)In addition to Eq. (2), the effect of the concrete damage on the diagonal strut is considered[11]; this can be expressed as

      (3)

      3)The contribution of the concrete to the shear capacity is represented by a diagonal compression strut only, and the effect of shear-span to effective depth ratio is considered[12]as Eq. (4).

      (4)

      4)The formula used inCodeforDesignofCompositeStructures(JGJ 138-2012)[22]andTechnicalSpecificationforConcreteStructuresofTallBuildings(JGJ 3-2010)[23]was based on the shear failure of steel plate-encased concrete composite shear walls and analogically modified for the shear capacity of CFDSPCWs under small shear-span ratios and zero axial loads[14], as shown below.

      Vu=0.5fyAs+0.5fcAc(0.7-fc/200)

      (5)

      wherefyis the yield strength of the steel plates;fcuandfcare the compressive strength of the standard concrete cube and prisms, respectively;θis the angle of diagonal tension strips with respect to the horizon;AsandAcare the total cross section area of the steel plate and concrete core along the span, respectively; andλis the shear-span ratio of the wall.

      In accordance with the above-mentioned shear mechanism, the critical parameters for the shear resistance of CFDSPCWs includes the mechanical and geometric properties of concrete and steel plates. Therefore, the strength of the concrete, the thickness of the steel plate and the concrete plate, and the height-width ratio of the wall are used for parametric studies. It should be noted that the height-width ratio is similar to the shear-span ratio of walls, but the former is always a little bit smaller. In addition, the interval between the stud connectors is a critical parameter that ensures the composite effect of the CFDSPCW, and thus is used for parametric study as well.

      4 Parametric analysis of the shear resistance of CFDSPCWs

      Parametric analyses were performed to investigate the effects of several critical parameters on the shear resistance of CFDSPCWs, which included the interval between the stud connectors, the thickness of the steel plate and the concrete plate, the strength of the concrete and the height-width ratio of the wall on the shear performance of CFDSPCWs.

      4.1 Effect of the interval between stud shear connectors

      Specimens W0, W21 and W22 in Table 1 were used to study the effect of the interval between the stud connectors (ds) on the shear resistance of CFDSPCWs, and the interval changed from 200 mm to 600 mm.

      Fig.5(a) shows the load-displacement curves of CFDSPCWs. The curves are the same at the elastic stage, indicating that the interval between the stud connectors had only a minor effect on the initial elastic stiffness of the CFDSPCWs. Whendswas smaller than 300 mm, the load-displacement curves have no obvious softening part. The capacity of CFDSPCWs slightly increases with increasing displacement and changes to the plastic stage smoothly. However, whendswas equal to 600 mm, the curve slightly softens after the ultimate capacity.

      Fig.5 Effect of the space between stud connectors

      Fig.6 Displacement contours of steel plates at different intervals between stud connectors

      4.2 Effect of the height-width ratio of the wall

      Specimens W0, W11, W12, W13 and W14 in Table 1 were used to study the effect of the height-width ratio of the walls () on the shear resistance of CFDSPCWs, in whichchanges from 0.8 to 2.

      Fig.7 Effect of the depth-span ratio of the wall

      4.3 Effect of the thickness of the steel plate

      Specimens W0, W31, W32 and W33 in Table 1 were used to study the effect of the thickness of a steel plate (ts) on the shear resistance of CFDSPCWs, in which the plate’s thickness changed from 6 mm to 20 mm.

      Fig.8(a) shows that the load-displacement curves show no obvious softening, and the structure entered the plastic stage smoothly. With an increase ofts, the shear capacity of the CFDSPCW improves significantly. Fig.8(b) and (c) show that both the initial lateral stiffness and the shear capacity of the CFDSPCW increased linearly with the increase ofts.

      Fig.8 Effect of the thickness of steel plates on

      4.4 Effect of the thicknesses of the concrete plate

      Specimens W0, W41, W42 and W43 in Table 1 were used to study the effect of the thickness of a concrete plate (tc) on the shear resistance of CFDSPCWs, in which the thickness changed from 200 mm to 700 mm.

      Fig.9(a) shows that the load-displacement curves display no obvious softening, and the structure entered the plastic stage smoothly due to the good composite effect of the concrete and steel plates. Astcincreased, the shear capacity of the CFDSPCWs improved significantly. Moreover, Fig.9(b) and (c) demonstrate that both the initial lateral stiffness and the shear capacity increased linearly with an increase oftc. In CFDSPCWs, the concrete plate between the steel plates bears the lateral load and provides lateral stiffness, and also prevents the out-of-plane buckling of the steel plates. However, after taking the weight and the space of the structure into consideration, the thickness of concrete plate should not be too large.

      Fig.9 Effect of the thickness of the concrete plate

      4.5 Effect of the strength of the concrete

      Specimens W0, W51, W52, W53 and W54 in Table 1 were used to study the effect of the strength of the concrete (fcuk) on the shear resistance of the CFDSPCWs in which the strength changed from 20 MPa to 80 MPa.

      Fig.10(a) shows that the initial elastic lateral stiffness at the elastic stage gradually increased as the strength of the concrete increased. Fig.10(b) shows that the shear capacity of the CFDSPCWs rises linearly as the strength of the concrete increases. Furthermore, the higher strength of concrete can reduce the wall’s weight and requires less space for the structure. As a result, the shear capacity of CFDSPCWs could be improved by using high strength concrete, especially for high-rise buildings.

      Fig.10 Effect of the strength of concrete

      4.6 Comparisons of numerical and analytical results

      Fig.11 shows the comparisons of the peak capacities predicted by Eqs.(2)~(5) and the current numerical analysis. Clearly, the numerical results reasonably agree with the predicted results in terms of the effects of different parameters; and the relative errors between the numerical results and, for example, Eq.(2), are about 9%-19%. Therefore, the numerical results are generally larger, indicating that the results of Eqs.(2)~(5) are on the safe side.

      Fig.11 Comparisons of the peak capacities predicted by Eqs.(2)~(5) and the current numerical

      5 Conclusions

      This paper presents the results of extensive studies of the shear resistance of CFDSPCWs. Based on the relevant parametric analyses, the conclusions are as stated below:

      1) The interval between the stud connectors significantly affected the shear performance of the CFDSPCWs. Intervals between stud connectors that were not larger than 300 mm were able to effectively prevent the plates from out-of-plane buckling, and prevent the degradation of the shear capacity of the CFDSPCWs.

      2) In accordance with the assumption that the frame beams and columns surrounding CFDSPCWs are hinge connected and are rigid, the height-width ratio of the wall had a notable effect on the initial elastic stiffness, and aminor effect on the shear capacity of the CFDSPCWs.

      3) The shear resistance of CFDSPCWs can be improved by increasing the thickness of the steel and the concrete plate and the strength of the concrete. But, after taking the weight and the space of the structure into consideration, the thickness of the concrete plate should not be too large.

      Acknowledgements

      The authors are grateful for support from the National Natural Science Foundation of China(Grant No.51608168), the Fundamental Research Funds for the Central Universities (No. 2017B16014; 2019B12814).

      响水县| 张家界市| 邳州市| 江津市| 梅河口市| 方城县| 英山县| 宝丰县| 乌恰县| 措美县| 花莲县| 玉溪市| 合阳县| 和政县| 久治县| 南涧| 额尔古纳市| 深泽县| 拜城县| 琼结县| 上饶县| 金门县| 塔河县| 宁城县| 成安县| 同德县| 青冈县| 南昌市| 昭平县| 长沙市| 肃北| 故城县| 石河子市| 彭水| 乌兰察布市| 泰宁县| 于都县| 栾城县| 潍坊市| 南川市| 大兴区|