• 
    

    
    

      99热精品在线国产_美女午夜性视频免费_国产精品国产高清国产av_av欧美777_自拍偷自拍亚洲精品老妇_亚洲熟女精品中文字幕_www日本黄色视频网_国产精品野战在线观看

      ?

      第二代雙源CT大螺距模式低輻射劑量血管成像進(jìn)展

      2016-05-13 03:44:56徐佳歡孫凱
      關(guān)鍵詞:掃描模式螺距雙源

      徐佳歡 孫凱

      014040,包頭醫(yī)學(xué)院(徐佳歡);014040,包頭市中心醫(yī)院影像科(徐佳歡、孫凱)

      第二代雙源CT大螺距模式低輻射劑量血管成像進(jìn)展

      徐佳歡 孫凱

      014040,包頭醫(yī)學(xué)院(徐佳歡);014040,包頭市中心醫(yī)院影像科(徐佳歡、孫凱)

      雙源CT應(yīng)用臨床以來,在CT血管造影方面越來越顯示出其獨(dú)特優(yōu)勢(shì),其較高的時(shí)間和空間分辨率及較快的掃描速度使獲得高質(zhì)量的圖像成為可能。雙源CT大螺距掃描模式在血管成像方面具有圖像質(zhì)量好、有效射線劑量低、掃描時(shí)間快等優(yōu)點(diǎn)。筆者就第二代雙源CT大螺距模式在血管成像方面的進(jìn)展及臨床應(yīng)用價(jià)值進(jìn)行綜述。

      體層攝影術(shù),螺旋計(jì)算機(jī);輻射劑量;CT血管成像

      Fund programs:Nation Natural Science Foundation of China(81560286);Inner Mongolia Autonomous Region Health and Family Planning Commission(201302124)

      近年來,隨著多層螺旋CT技術(shù)的飛速發(fā)展,CT血管成像(computed tomography angiography,CTA)以其檢查的無創(chuàng)性、快捷性和準(zhǔn)確性等優(yōu)點(diǎn)得到了廣泛應(yīng)用[1-2],但伴隨而來的較高輻射劑量也越來越引起人們的關(guān)注。2009年,第二代雙源CT問世,它的時(shí)間分辨率達(dá)到75 ms,掃描速度45 cm/s,最大螺距3.4。雙源CT的大螺距掃描模式,又稱Flash spiral模式(Flash模式)。它實(shí)現(xiàn)了前瞻性螺旋掃描單個(gè)心動(dòng)周期心臟成像,采集數(shù)據(jù)時(shí)間減少到0.25 s,明顯降低了有效射線量。雙源CT大螺距血管成像使得CT血管造影在很大程度上滿足了臨床的各種需要,使CT血管造影技術(shù)又達(dá)到了一個(gè)新高度。

      1 大螺距掃描模式原理

      2006年,第一代雙源CT問世,它由兩個(gè)相互成90°角的X線球管和兩組64層探測(cè)器構(gòu)成,每組探測(cè)器包括40排探測(cè)器,時(shí)間分辨率為83 ms,空間分辨率為0.33 m,最大螺距1.5,兩套X線系統(tǒng)每套最大功率為80 kV,每個(gè)球管都可以分別設(shè)置為80、100、120、140 kV,從而可進(jìn)行雙能量數(shù)據(jù)采集。2009年,第二代雙源CT應(yīng)用于臨床,機(jī)架內(nèi)的兩套X線球管呈94°角放置,兩套對(duì)應(yīng)的探測(cè)器系統(tǒng)增加到128層,時(shí)間分辨率提高至75 ms,空間分辨率為0.17 mm,最大螺距提高至3.4,兩套X線系統(tǒng)最大功率提升為100 kV,利用能譜純化技術(shù),實(shí)現(xiàn)了前瞻性大螺距掃描。在對(duì)冠狀動(dòng)脈及主、肺動(dòng)脈的掃描時(shí),能以較快的速度及較低的輻射劑量取得較好的圖像質(zhì)量。另外,原始數(shù)據(jù)的迭代重建技術(shù)可以雙重減少噪聲和偽影,大大增加圖像信噪比,大幅度降低了輻射劑量。

      2 雙源CT大螺距模式低輻射劑量冠狀動(dòng)脈成像

      2.1 低心率患者的大螺距模式成像

      前瞻性心電門控技術(shù)、大螺距掃描模式、較快的進(jìn)床速度以及0.28 s/圈的旋轉(zhuǎn)時(shí)間促使兩組球管-探測(cè)器在大螺距旋轉(zhuǎn)掃描模式下能在1/4機(jī)架旋轉(zhuǎn)時(shí)間內(nèi)覆蓋整個(gè)心臟容積范圍,從而滿足在一個(gè)心動(dòng)周期內(nèi)完成整個(gè)心臟的掃描。Achenbach等[3]對(duì)不同心率患者的雙源CT冠狀動(dòng)脈圖像質(zhì)量進(jìn)行評(píng)價(jià)發(fā)現(xiàn),心率≤80次/min患者的最佳成像時(shí)間窗為RR間期的70%;Husmann等[4]研究認(rèn)為,心率<60次/min最佳成像時(shí)間窗選擇為RR間期的50%~60%。低心率患者采用回顧性心電門控模式時(shí),利用冠狀動(dòng)脈舒張末期低速平臺(tái),采集時(shí)相選擇為RR間期的70%~80%;采用Flash模式時(shí),由于單個(gè)心動(dòng)周期成像,掃描時(shí)間至少需要250 ms,如果在RR間期的70%~80%成像,則會(huì)落入下一周期的P波后產(chǎn)生偽影,因此,大螺距雙源CT默認(rèn)的掃描時(shí)間窗為RR間期的55%或60%[5]。

      2.2 高心率患者的大螺距模式成像

      Goetti等[6]對(duì)心率≥70次/min的患者采用大螺距前瞻性心電門控進(jìn)行冠狀動(dòng)脈血管成像,結(jié)果發(fā)現(xiàn),高心率患者在RR間期的30%成像,不可診斷的血管節(jié)段為2.8%,采用RR間期的60%采集數(shù)據(jù)成像,不可診斷的血管節(jié)段高達(dá)8.3%。Sun等[7]研究顯示,高心率患者(平均心率90次/min)采用Flash模式在RR間期的20%~30%成像可獲得較好的圖像質(zhì)量,不可診斷的冠狀動(dòng)脈節(jié)段僅為1.5%,這在以往的多層螺旋CT是難以達(dá)到的。另有研究表明,隨著心率的增加,采用收縮期采集數(shù)據(jù)成像可降低偽影的發(fā)生[8]。

      2.3 冠狀動(dòng)脈支架患者的大螺距模式成像

      對(duì)支架植入術(shù)后的評(píng)價(jià),傳統(tǒng)的多層螺旋CT的時(shí)間分辨率較低,支架的線束硬化偽影致使冠狀動(dòng)脈成像的圖像質(zhì)量較差,多層螺旋CT對(duì)支架內(nèi)管腔觀察受限,尤其對(duì)<3.5 mm的支架內(nèi)再狹窄診斷受限。有研究發(fā)現(xiàn),雙源CT診斷支架內(nèi)再狹窄的靈敏度為85.7%,特異度為95.7%,當(dāng)支架直徑>2.75 mm時(shí),診斷支架內(nèi)再狹窄的靈敏度與特異度均為100%[9]。另有研究顯示,雙源CT診斷支架直徑≥3.50 mm、支架直徑=3.00 mm和支架直徑≤2.75 mm的再狹窄特異度分別為100%、80%和 66%,陽性預(yù)測(cè)值分別為100%、95%和53%[10]。Wang等[11]研究結(jié)果顯示,在173例支架植入術(shù)后的患者中,有156例獲得了較好的圖像質(zhì)量,44例支架直徑<3 mm的患者中,冠狀動(dòng)脈CTA發(fā)現(xiàn)有10例患者發(fā)生支架內(nèi)再狹窄,而同樣行冠狀動(dòng)脈血管造影僅發(fā)現(xiàn)9例。由此可見,雙源CT診斷支架內(nèi)再狹窄有較好的可行性,支架內(nèi)徑是影響支架內(nèi)腔成像的關(guān)鍵因素。

      2.4 冠狀動(dòng)脈旁路移植術(shù)后雙源CT大螺距模式成像

      冠狀動(dòng)脈旁路移植術(shù)后5年內(nèi)有25%的患者發(fā)生橋血管的狹窄或閉塞,隨訪復(fù)查至關(guān)重要。由于橋血管較長,因此,冠狀動(dòng)脈搭橋術(shù)后患者冠狀動(dòng)脈CT成像掃描范圍較常規(guī)掃描范圍大,輻射劑量高。Lee等[12]研究顯示,使用Flash模式的輻射劑量可較回顧性心電門控掃描模式降低65%左右。Heye等[13]利用二代雙源CT評(píng)價(jià)110條橋血管,診斷靈敏度和特異度分別為97.9%和100%,Goetti等[14]同樣利用第二代雙源CT評(píng)價(jià)125條橋血管的465個(gè)血管節(jié)段,不可診斷的血管比例僅為0.6%,有效劑量為2.3 mSv。由此可見,雙源CT對(duì)橋血管狹窄或閉塞的診斷準(zhǔn)確性優(yōu)于多層螺旋CT。

      2.5 冠狀動(dòng)脈低輻射劑量大螺距模式成像

      冠狀動(dòng)脈CT成像的主要局限性是對(duì)人體的電離輻射,一項(xiàng)評(píng)價(jià)冠狀動(dòng)脈輻射劑量的多中心臨床研究顯示,采用傳統(tǒng)的回顧性心電門控平均有效劑量為12 mSv[15]。根據(jù)放射防護(hù)最優(yōu)化合理使用劑量原則,在滿足診斷需求的前提下,應(yīng)盡可能降低輻射劑量。雙源CT Flash模式其螺距可高達(dá)3.4,根據(jù)容積 CT劑量指數(shù)(computed tomographic dose index,CTDIvol)的定義(CTDIvol=CTDIw/CT螺距因子)可知,螺距越大,劑量越低。雙源CT結(jié)合低管電壓及迭代重建方法,在保證冠狀動(dòng)脈圖像質(zhì)量的同時(shí),應(yīng)將輻射劑量降低到1mSv以下[16-18]。Fuchs等[19]報(bào)道,冠狀動(dòng)脈CTA輻射劑量僅為0.21 mSv,接近普通X射線劑量。另有報(bào)道,低體重患者輻射劑量可低至0.1 mSv[20]。

      雙源CT冠狀動(dòng)脈CTA有效輻射劑量見表1。

      3 雙源CT大螺距模式主動(dòng)脈成像

      主動(dòng)脈夾層是主動(dòng)脈疾病中常見的病變之一,多層螺旋CT診斷主動(dòng)脈夾層的靈敏度和特異度接近100%,但多層螺旋CT由于時(shí)間分辨率的限制,主動(dòng)脈根部產(chǎn)生明顯運(yùn)動(dòng)偽影造成主動(dòng)脈夾層假陽性或根竇部不能評(píng)價(jià),且輻射劑量大,一次掃描的輻射劑量為12~14 mSv。近年來,一系列減少輻射劑量的掃描方法應(yīng)用于臨床,如大螺距掃描模式,降低管電壓、管電流模式。Apfaltrer等[24]對(duì)110例患者分別采用大螺距模式和傳統(tǒng)模式行主動(dòng)脈成像,結(jié)果顯示,主動(dòng)脈的圖像質(zhì)量在兩種模式下具有較高的一致性,而有效輻射劑量卻僅為傳統(tǒng)掃描模式的50%[(9.6±3.0)mSv vs.(19.8±8.2)mSv]。Bolen等[25]的研究同樣顯示,大螺距模式下的主動(dòng)脈成像圖像質(zhì)量清晰,輻射劑量僅為(5.4±1.8)mSv。雙源CT大螺距主動(dòng)脈掃描在減少患者輻射劑量及提高圖像質(zhì)量方面具有獨(dú)特優(yōu)勢(shì),能為主動(dòng)脈病變的及時(shí)檢出提供準(zhǔn)確顯示和評(píng)價(jià),進(jìn)而有助于醫(yī)生早期制定治療方案。

      表1 雙源CT冠狀動(dòng)脈CT血管成像有效輻射劑量Table 1 Dual-source CT coronary CT artery effective radiation dose

      4 雙源CT大螺距模式肺動(dòng)脈成像

      肺動(dòng)脈栓塞是急診常見病,病死率高。肺動(dòng)脈CT血管成像憑借著其較高的靈敏度與特異度成為診斷肺動(dòng)脈栓塞的主要方法。但是,傳統(tǒng)的肺動(dòng)脈CT血管成像需要患者屏氣且輻射劑量偏高,難以克服呼吸運(yùn)動(dòng)偽影的影響。大螺距掃描模式突破了上述限制,圖像質(zhì)量高,可明顯降低輻射劑量。有研究在肺動(dòng)脈CTA中,比較雙源CT大螺距模式、雙能量模式、傳統(tǒng)128層螺旋CT模式及64層CT 4種掃描模式的圖像質(zhì)量與輻射劑量,結(jié)果顯示,雙源CT大螺距模式下輻射劑量最低,僅為2.34 mSv,其他分別為3.24、3.58、4.21 mSv[26]。Lu等[27]將100例懷疑肺栓塞患者隨機(jī)分為兩組,分別行普通模式和大螺距模式肺動(dòng)脈掃描,結(jié)果顯示,大螺距模式的輻射劑量低于1 mSv,與普通組相比,輻射劑量降低了50.3%,對(duì)比劑用量僅為20 mL,是普通組對(duì)比劑用量的1/3,但兩者的圖像質(zhì)量相當(dāng)。Bauer等[28]研究顯示,大螺距模式下的肺動(dòng)脈CT成像可以在自由呼吸下進(jìn)行,有效劑量為(1.99±0.43)mSv,圖像質(zhì)量清晰,可供臨床診斷。雙源CT較高的空間分辨率有效避免了心跳呼吸帶來的偽影,患者無需屏氣即可完成檢查,重建后的薄層圖像經(jīng)最大密度投影、多平面重組、曲面重建、容積再現(xiàn)等后處理工作站技術(shù)實(shí)現(xiàn)多種圖像重組,通過比較分析,能清楚顯示肺動(dòng)脈形態(tài)、管徑及周圍解剖關(guān)系,更有助于肺段及亞段肺栓塞的檢出以達(dá)到最佳診斷效果,雙源CT大螺距模式以其獨(dú)特的優(yōu)勢(shì)為低輻射劑量的肺動(dòng)脈成像的研究提供了方向。

      5 雙源CT大螺距模式心腦血管聯(lián)合成像

      動(dòng)脈粥樣硬化是一種全身性疾病,冠狀動(dòng)脈粥樣硬化與頸動(dòng)脈、腦動(dòng)脈粥樣硬化密切相關(guān)。傳統(tǒng)的多層螺旋CT對(duì)頭頸部及冠狀動(dòng)脈血管造影需要分2次進(jìn)行,且輻射劑量高,對(duì)比劑用量大,操作復(fù)雜。Wang等[29]研究發(fā)現(xiàn),利用雙源CT大螺距模式對(duì)47例患者進(jìn)行心腦血管聯(lián)合掃描其平均輻射劑量為3.58 mSv,利用前瞻性序列掃描模式對(duì)51例患者行冠狀動(dòng)脈CTA,其平均輻射劑量為3.56 mSv,二者輻射劑量值相當(dāng),而前者使用了65 mL對(duì)比劑獲得了3個(gè)部位的數(shù)據(jù),顯著降低了輻射劑量及對(duì)比劑用量。Sun等[30]應(yīng)用雙源CT大螺距模式進(jìn)行心腦血管“一站式”聯(lián)合掃描,即單次注射對(duì)比劑完成心臟和頭頸血管3個(gè)部位的掃描,圖像質(zhì)量與傳統(tǒng)分次掃描無顯著差異,平均輻射劑量僅為1.4 mSv,對(duì)比劑用量為分次掃描的1/2。雙源CT掃描模式心臟和頭頸動(dòng)脈“一站式”聯(lián)合CTA掃描,為檢測(cè)心腦血管病變提供了低輻射劑量、高圖像質(zhì)量的無創(chuàng)性方法。為早期干預(yù)、降低心腦血管事件的發(fā)生提供依據(jù),具有重要臨床意義。

      6 展望

      綜上所述,第二代雙源CT極大地提高了時(shí)間分辨率,以其較高的準(zhǔn)確率,較清晰的圖像質(zhì)量及超低的輻射劑量,基本滿足了臨床血管疾病檢查的需要。2014年,第三代雙源CT應(yīng)用于臨床,時(shí)間分辨率提高至66 ms,機(jī)架旋轉(zhuǎn)速度達(dá)到0.25 s,冠狀動(dòng)脈成像僅0.13 s。其大螺距模式又稱Turbo Flash模式,第三代雙源CT大螺距掃描有望進(jìn)一步提高圖像質(zhì)量,降低輻射劑量,值得臨床進(jìn)一步研究。

      利益沖突 本研究由署名作者按以下貢獻(xiàn)聲明獨(dú)立開展,不涉及任何利益沖突。

      作者貢獻(xiàn)聲明 徐佳歡負(fù)責(zé)論文撰寫;孫凱負(fù)責(zé)提出命題、論文審閱。

      [1]中華放射學(xué)雜志心臟冠狀動(dòng)脈多排CT臨床應(yīng)用協(xié)作組.心臟冠狀動(dòng)脈多排CT臨床應(yīng)用專家共識(shí)[J].中華放射學(xué)雜志,2011, 45(1):9-17.DOI:10.3760/cma.j.issn.1005-1201.2011.01.003. Chinese Journal of Radiology Heart Coronary Artery Multi-Detector Row CT Clinical Applications of Collaboration.Expert consensus document of Chinese Journal of Radiology on clinical applications of cardiac and coronary artery imaging by multi-detector row CT[J]. Chin J Radiol,2011,45(1):9-17.

      [2]Westwood ME,Raatz HD,Misso K,et al.Systematic review of the accuracy of dual-source cardiac CT for detection of arterial stenosis in difficult to image patient groups[J].Radiology,2013,267(2):387-395.DOI:10.1148/radiol.13121136.

      [3]Achenbach S,Manolopoulos M,Schuhbaeck AA,et al.Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries [J].J Cardiovasc Comput Tomogr,2012,6(2):91-98.DOI:10. 1016/j.jcct.2011.11.006.

      [4]Husmann L,Leschka S,Desbiolles L,et al.Coronary artery motion and cardiac phases:dependency on heart rate-implications for CT image reconstruction[J].Radiology,2007,245(2):567-576.DOI:10.1148/radiol.2451061791.

      [5]孫凱,韓瑞娟,李坤成.心臟電-機(jī)械耦聯(lián)與雙源CT冠狀動(dòng)脈成像最佳成像時(shí)間窗[J].中華臨床醫(yī)師雜志:電子版,2013,7(23):10875-10879.DOI:10.3877/cma.j.issn.1674-0785.2013.23. 111. Sun K,Han RJ,Li KC.Cardiac electrical mechanical coupling and the optimal electrocardiographic pulsing Windows for Dual-source CT coronary angiography[J].Chin J Clinicians(Electronic Edition), 2013,7(23):10875-10879.

      [6]Goetti R,Feuchtner G,Stolzmann P,et al.High-pitch dual-source CT coronary angiography:systolic data acquisition at high heart rates[J].Eur Radiol,2010,20(11):2565-2571.DOI:10.1007/ s00330-010-1838-z.

      [7]Sun K,Han RJ,Cui LF,et al.Feasibility and diagnostic accuracy for assessment of coronary artery stenosis of prospectively electrocardiogram-gated high-pitch spiral acquisition mode dual-source CT coronary angiography in patients with relatively higher heart rates:in comparison with catheter coronary angiography[J].Chin Med Sci,2013,27(4):213-219.

      [8]孫凱,韓瑞娟,趙瑞平,等.不同心率患者采用大螺距雙源CT冠狀動(dòng)脈成像的圖像質(zhì)量及影響因素分析[J].中華放射學(xué)雜志,2012,46(9):773-778.DOI:10.3760/cma.j.issn.1005-1201.2012.09.001. Sun K,Han RJ,Zhao RP,et al.The image quality and influencing factors of high-pitch dual-source CT coronary angiography in patients with different heart rates[J].Chin J Radiol,2012,46(9):773-778.

      [9]孔令燕,劉冬,王怡寧,等.雙源CT冠狀動(dòng)脈成像評(píng)價(jià)冠狀動(dòng)脈支架通暢性[J].中國醫(yī)學(xué)科學(xué)院學(xué)報(bào),2010,32(6):601-606.DOI:10.3881/j.issn.1000-503X.2010.06.002. Kong LY,Liu D,Wang YN,et al.Assessment of coronary stent lumen visibility and patency by Dual-source computed tomographic Angiography[J].Acta Acad Med Sin,2010,32(6):601-606.

      [10]羊鎮(zhèn)宇,王強(qiáng),郭素峽,等.雙源CT在冠狀動(dòng)脈支架內(nèi)再狹窄診斷中的價(jià)值[J].中華心血管病雜志,2011,39(1):49-52. DOI:10.3760/cma.j.issn.0253-3758.2011.01.010. Yang ZY,Wang Q,Guo SX,et al.Value of detecting in-stent restenosis by dual source coronary computed tomography coronary angiography[J].Chin J Cardiol,2011,39(1):49-52.

      [11]Wang LF,Tao LW,Huang MX,et al.Clinical evaluation of coronary in-stent restenosis using dual-source computed tomography[J]. Echocardiography,2015,32(11):1681-1687.DOI:10.1111/ echo.12932.

      [12]Lee YW,Yang CC,Mok GS,et al.Prospectively versus retrospectively ECG-gated 256-slice CT angiography to assess coronary artery bypass grafts-comparison of image quality and radiation dose [J/OL].PLoS One,2012,7(11):e49212[2016-04-10].http:// journals.plos.org/plosone/article?id=10.1371/journal.pone.0049212. DOI:10.1371/journal.pone.0049212.

      [13]Heye T,Kauczor HU,Szabo G,et al.Computed tomography angiography of coronary artery bypass grafts:robustness in emergency and clinical routine settings[J].Acta Radiol,2014,55(2):161-170. DOI:10.1177/0284185113494977.

      [14]Goetti R,Leschka S,Baumueller S,et al.Low dose High-Pitch spiral acquisition 128-Slice Dual-Source computed tomography for the evaluation of coronary artery bypass graft patency[J].Invest Radiol, 2010,45(6):324-330.DOI:10.1097/RLI.0b013e3181dfa47e.

      [15]Einstein AJ,Wolff SD,Manheimer ED,et al.Comparison of image quality and radiation does of coronary computed tomographic angiography between conventional helical scanning and a strategy incorporating sequential scanning[J].Am J Cardiol,2009,104(10):1343-1350.DOI:10.1016/j.amjcard.2009.07.003.

      [16]Zheng MW,Wu YJ,Wei MQ,et al.Low-Concentration contrast medium for 128-Slice Dual-Source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-Pitch spiral acquisition[J].Acad Radiol,2015,22(2):195-202. DOI:10.1016/j.acra.2014.07.025.

      [17]Marwan M,Mettin C,Pflederer T,et al.Very low-dose coronaryartery Calcium scanning with high-pitch spiral acquisition mode:comparison between 120-kV and 100-kV tube voltage protocols[J].J Cardiovasc Comput Tomogr,2013,7(1):32-38.DOI:10.1016/ j.jcct.2012.11.004.

      [18]Zhang LJ,Qi L,De Cecco CN,et al.High-Pitch coronary CT angiography at 70 kVp with low contrast medium volume comparison of 80 and 100 kVp High-Pitch protocols[J].Medicine(Baltimore), 2014,93(22):18.DOI:10.1097/MD.0000000000000092.

      [19]Fuchs TA,Stehli J,Bull S,et al.Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination[J].Eur Heart J, 2014,35(17):1131-1136.DOI:10.1093/eurheartj/ehu053.

      [20]Schuhbaeck A,Achenbach S,Layritz C,et al.Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose<0.1 mSv using high-pitch spiral acquisition and raw databased iterative reconstruction[J].Eur Radiol,2013,23(3):597-606.

      [21]Koplay M,Kizilca O,Cimen D,et al.Prospective ECG-gated highpitch dual-source cardiac CT angiography in the diagnosis of congenital cardiovascular abnormalities:Radiation dose and diagnostic efficacy in a pediatric population[J/OL].Diagn Interv Imaging, 2016,pii:S2211-5684(16)30078-X[2016-04-10].http://www.sciencedirect.com/science/article/pii/S221156841630078X.DOI:10.1016/j.diii.2016.03.014.

      [22]Koplay M,Celik M,Avc? A,et al.Comparison between prospectively electrocar diogram-Gated high-pitch mode and retrospectively electrocardiogram-gated mode for dual-source CT coronary angiography[J/OL].Pol J Radiol,2015,80:561-568[2016-04-10].http:www.ncbi.nlm.gov/pmc/articles/PMC4699622.DOI:10.12659/ PJR.895232.eCollection 2015.

      [23]Matsubara K,Sakuda K,Nunome H,et al.128-slice dual-source CT coronary angiography with prospectively electrocardiography-triggered high-pitch spiral mode:radiation dose,image quality,and diagnostic acceptability[J].Acta Radiol,2016,57(1):25-32.DOI: 10.1177/0284185114562467.

      [24]Apfaltrer P,Hanna EL,Schoepf U,et al.Radiation dose and image quality at High-Pitch CT angiography of the aorta:intraindividual and interindividual comparisons with conventional CT angiography [J].AJR Am J Roentgenol,2012,199(6):1402-1409.DOI:10.2214/AJR.12.8652.

      [25]Bolen MA,Popovic ZB,Tandon N,et al.Image quality,contrast enhancement,and radiation dose of ECG-triggered high-pitch CT versus non-ECG-triggered standard-pitch CT of the thoracoabdominal aorta[J].AJR Am J Roentgenol,2012,198(4):931-938.

      [26]戴穎鈺,馬新星,陳銦銦,等.四種CT掃描模式對(duì)肺動(dòng)脈成像圖像質(zhì)量和輻射劑量的影響[J].中國醫(yī)學(xué)影像學(xué)雜志,2015,23(1):4-7,9.DOI:10.3969/j.issn.1005-5185.2015.01.002.Dai YY,Ma XX,Chen YY,et al.Effect of four CT scan modes on image quality and radiation dose of pulmonary angiography[J].Chin J Med Imaging,2015,23(1):4-7,9.

      [27]Lu GM,Luo S,Meinel FG,et al.High-pitch computed tomography pulmonary angiography with iterative Reconstruction at 80 kVp and 20 mL contrast agent volume[J].Eur Radiol,2014,24(12):3260-3268.DOI:10.1007/s00330-014-3365-9.

      [28]Bauer RW,Schell B,Beeres M,et al.High-pitch dual-source computed tomography pulmonary angiography in freely breathing patients[J].J Thorac Imaging,2012,27(6):376-381.DOI:10.1097/ RTI.0b013e318250067e.

      [29]Wang ZW,Chen Y,Wang Y,et al.Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary,head and neck arteries[J/OL].PLoS One,2014,9(3):e90268[2016-04-10].http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0090268.DOI:10.1371/journal.pone.0090268.

      [30]Sun K,Li K,Han R,et al.Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries[J].Eur J Radiol,2015,84(3):398-406.DOI:10.1016/j.ejrad.2014.11.009.

      Application of high-pitch and low-dose mode using dual-source CT by computed tomography angiography

      Xu Jiahuan,Sun Kai
      Baotou Medical College,Baotou 014040,China(Xu JH);Department of Image,Baotou Central Hospital, Baotou 014040,China(Xu JH,Sun K)

      Sun Kai,Email:Henrysk@163.com

      Given the unique advantages of dual-source computed tomography(DSCT),such as high temporary and spatial resolutions and fast scanning speed,its application in angiography has made possible for high-quality images to be obtained.In high-pitch scanning mode,DSCT can obtain high-quality angiography images with low effective radiation dose at a short scan time.This paper reviewed the progress and clinical applications of high-pitch mode DSCT in computed tomography angiography.

      Tomography,spiral computed;Radiation dosage;Computed tomography angiography

      孫凱,Email:Henrysk@163.com

      10.3760/cma.j.issn.1673-4114.2016.04.011

      2016-04-11)

      國家自然科學(xué)基金(81560286);內(nèi)蒙古自治區(qū)衛(wèi)生和計(jì)劃生育委員會(huì)項(xiàng)目(201302124)

      猜你喜歡
      掃描模式螺距雙源
      變螺距螺紋數(shù)控車削技巧
      氣質(zhì)聯(lián)用中性丟失掃描定性含氯化合物的方法
      常用粗牙螺紋螺距簡易計(jì)算公式及應(yīng)用
      雙源采購跳躍-擴(kuò)散庫存控制模型
      雙光能X射線骨密度儀測(cè)量腰椎骨密度不同掃描模式的對(duì)比研究*
      雙源CT大螺距掃描在胸部篩查的應(yīng)用
      雙源信號(hào)深組合導(dǎo)航在新一代運(yùn)載火箭制導(dǎo)系統(tǒng)中應(yīng)用初探
      某調(diào)距槳螺距振蕩控制分析
      船海工程(2012年4期)2012-01-22 10:29:22
      冠狀動(dòng)脈閉塞支的雙源CT評(píng)價(jià)
      第二代雙源CT雙能掃描模式對(duì)胰腺癌的影像診斷價(jià)值初探
      康马县| 名山县| 新龙县| 古交市| 买车| 阿巴嘎旗| 专栏| 米易县| 赤壁市| 河池市| 镶黄旗| 高唐县| 哈密市| 溧水县| 台安县| 莱州市| 呈贡县| 深泽县| 济南市| 鲁山县| 新野县| 永顺县| 英吉沙县| 临沧市| 巴里| 湖州市| 大港区| 淮安市| 虎林市| 于田县| 兖州市| 察雅县| 黄大仙区| 鄱阳县| 郸城县| 阿拉善盟| 陆丰市| 阳新县| 林周县| 克山县| 鄂托克前旗|