• 
    

    
    

      99热精品在线国产_美女午夜性视频免费_国产精品国产高清国产av_av欧美777_自拍偷自拍亚洲精品老妇_亚洲熟女精品中文字幕_www日本黄色视频网_国产精品野战在线观看 ?

      Simulating the Three-Dimensional Image of Cold Atomic Cloud

      2016-06-05 14:58:29PENGYu
      光譜學(xué)與光譜分析 2016年12期
      關(guān)鍵詞:三軸北京林業(yè)大學(xué)半軸

      PENG Yu

      1. School of Science,Beijing Forestry University,Beijing 100083,China 2. Center for Quantum Information,IIIS,Tsinghua University,Beijing 100084,China

      Simulating the Three-Dimensional Image of Cold Atomic Cloud

      PENG Yu1,2

      1. School of Science,Beijing Forestry University,Beijing 100083,China 2. Center for Quantum Information,IIIS,Tsinghua University,Beijing 100084,China

      We propose a scheme for accurately simulating of the three-dimensional image of cold atomic cloud,which is more intuitive and stereoscopic than former two-dimensional image by probe laser. We have realized simulating of cold atomic cloud. The number of trapped atoms is about 108. The atomic cloud is about the geometric three-dimensional shape. Tri-axial ellipsoid with distinct semi-axis lengthsRx=1.06 mm,Ry=1.06 mm,Rz=0.57 mm,and the three-dimensional image of cold atomic cloud was simulated for the first time.

      Atom optics; Laser cooling; Lasers

      Introduction

      The concept of the magneto-optical trap (MOT) was first suggested by Jean Dalibard[1],when pioneers of the field such as Pritchard and Chu were still struggling with dipole trapping of neutral atoms[2-5]. The MOT was shown to be able to trap a much higher number of atoms (on the order of 107[3]),making it a preferred choice as a source of cold atoms. The MOT is a widely used technique,as the trap can produce ultracold atomic clouds with temperatures below 100 μK[6-7]. The two properties of the MOT cloud that we are most interested in are the number and the temperature and how they behave in different regimes.

      To measure these properties,we need methods to measure the cloud size,the number of atoms,and the expansion of the cloud. For cloud Radius,the fluorescence image of the cloud is taken using a grayscale CCD camera. The value in each pixel is averaged over many images to reduce noise due to the fluctuation in number of atoms[6]. For number of Atoms,the absorption method uses another weak laser beam as a probe and is aligned to pass through the cloud and is collected on a photodiode. The number of atoms inside the trap is measured by looking at the optical signal coming from either the fluorescence from the trapped atoms or the absorption of a probe beam[7]. For the expansion of the cloud,the ensemble of trapped atoms can have average velocity components that differ from dimension to dimension due to each dimension of the trap having different cooling and trapping forces[7].

      Here we propose a new method for determining three-dimensional image of cold atomic cloud for the first time. Compared to former two-dimensional image by probe laser[7],the three-dimensional image of cold atomic cloud is intuitive and stereoscopic.

      In order to trap a large ensemble of atoms,the atoms need to be cooled and confined to a specific location. The six cooling /repump beams and two detection beams are delivered from the optical table to the mot chamber using 10 m long SM-PM fibers. At the output end of the fibers,the beams are collimated with beam expanders that produce the desired beam size and polarization. Fig.1 show the schematic of the MOT.

      Fig.1 Schematic of magneto-optical trap

      The bronze rings represent the magnetic field coils in an anti-Helmholtz configuration. The red ball in the middle represents the atomic cloud. The pink arrows are the laser beams arranged in counter-propagating pairs of mutually orthogonal polarization. The fluorescence of atomic cloud is collected by detector.

      For a given MOT detuning,the atom number can be maximised by maximising the fluorescence (photodiode voltage). There are a number of parameters that can alter the atom number captured. Unfortunately most parameters are dependent on each other,which complicates the order of optimisation. The first step in optimisation is to determine the best Rb dispenser current. A compromise has to be made between obtaining high atom numbers and running the dispensers too hard,thus shortening their lifetime. Therefore running the dispensers at 3.7 A was chosen.

      Attention is now turned to optimising the detuning of the MOT cooling light. The maximum fluorescence does not necessarily correspond to the maximum atom number. Small detunings,being close to resonance,cause the MOT to oscillate and hence account for the large error. The maximum stable fluorescence occurs at -2π×12.5 MHz. The maximum atom number is now achieved with a frequency detuning of -2π×17 MHz.

      To estimate three-dimensional image of the trapped rubidium atoms in MOT,three shutters are arranged at three directions of counterpropagating to control the cooling and trapping light,shown in Fig.1[8]. And the light pulse is generated by controlling the on and off of shutters with the help of a time sequence controller.

      When the external trigger pulse from the time sequence controller has arrived,the shutter will work. The fluorescent signal of in-trap atoms cloud can easily be taken by the detector,and then show on oscilloscope. In order to take three-dimensional image of the trapped atoms,we control three directions of counterpropagating by shutters separately.

      Atoms that passed through the center laser overlapping region would be then captured into the MOT. Assuming there are no collisions between trapped atoms,the change in number of atoms with time is

      N(t)=N0(1-exp{-t/τ})

      (1)

      whereτis the lifetime of the trap is found by collecting the fluorescence signal during the loading,andN0is the steady state number of atoms. Therefore the fluorescent signal intensity

      I(t)=Ib+I(1-exp{-t/τ})

      (2)

      I(0)=Ibis the background signal.I(τ) is the fluorescence signal during the loading. A detuning of -2π×12.5 MHz produces an image of a large and stable cold atom cloud on the CCD camera. The repumping light detuning has a much higher tolerance and an atomic cloud is observed over a 2π×100 MHz range. The detuning is set by optimising the fluorescence seen on the CCD camera.

      本文從簡化代表庫、SLAF-seq技術(shù)以及基于限制性酶切的簡化基因組測序3方面介紹了簡化基因組測序技術(shù)的研究進展,為快速檢測出高密度的SNPs位點,建立高密度遺傳圖譜和分子標記開發(fā)提供參考.

      This equation 2 describes the dynamic of a MOT with a loading of atoms into MOT. We control three directions of counterpropagating by shutters separately to research the loading process of cold atomic atoms in 3 directions.

      Fig.2 MOT photodiode voltage (fluorescence) during trap loading by shuttering the trapping light ofX

      (a):Fluorescence signal collected by oscilloscope; (b):Loading procedure. A 3.69 s loading 1/e time was used.

      Firstly we close the shutterxand then open the shutterx(other two shutters are open in the procedure). The fluorescent signal is shown in Fig.2(a). The black signal is background noise when closing the shutterx,and the red signal is the fluorescence of atoms with three shutters opening. Loading procedure is shown in Fig.2(b). The loading time is extracted 3.69 s. The atom number saturates for a loading time greater than 14 seconds. 108cold atoms can be collected by the MOT. The exponential decay has a 1/e lifetime of 3.69 seconds. The fluorescence signal change during the loading is 229 mV.

      Figure 2 plots photodiode voltage against. The optimum fluorescence is achieved when a current of 5 A in the anti-Helmholtz configuration coils on the MOT is used,which corresponds to a magnetic field gradient of 5.2 G·cm-1.

      Secondly we close the shutteryand then open the shuttery(other two shutters are open in the procedure). The fluorescent signal is shown in Fig.3(a). The black signal is background noise when closing the shuttery,and the red signal is the fluorescence of atoms with three shutters opening. Loading procedure is shown in Fig.3(b). The loading time is extracted 3.76 s. The fluorescence signal change during the loading is 230 mV.

      Fig.3 MOT photodiode voltage (fluorescence) during trap loading by shuttering the trapping light ofY

      (a):Fluorescence signal collected by oscilloscope; (b):Loading procedure. A 3.76 s loading 1/e time was used.

      We take two-dimensional image of the trapped atoms by former common method by probe laser as comparison. The cloud radius is measured using the area fit method,and cloud radius inxdimension (horizontal in real setup) andydimension (gravity in real setup). The cloud radius inxdimension andydimension is shown in Fig.4. The data collection is controlled by a program written in LabVIEW which also controls the camera operation mode and exposure,and then handled in MATLAB by the area fit method.

      Fig.4 Image of in-trap atoms cloud

      The bright spot indicates the true cloud (1/eradius 0.99 mm×1.03 mm)

      By analysis of the loading time by shutteringxbeam andybeam,we found there are almost equal,shown in Fig.2 and Fig.3. Therefore we infer that the loading time represent the corresponding size of atomic cloud. In order to verify our conclusion,we measure the size of atomic cloud with former method with probe laser. We found the image of dimensionxand dimension y measured by former method are almost equal,shown in Fig.4. This result is the same as our new method. Therefore we conclude that the loading time ratio of dimensionxtoyis equal to the size ratio in dimensionxtoy. So we can get the image of atoms cloud by measuring the loading time.

      Thirdly we close the shutterzand then open the shutterz(other two shutters are open in the procedure). The fluorescent signal is shown in Fig.5(a). The black signal is background noise when closing the shutterz,and the red signal is the fluorescence of atoms with three shutters opening. Loading procedure is shown in Fig.5(b). The loading time is extracted 2.04 s. The fluorescence signal change during the loading is 173 mV.

      By analysis of the loading time by shutteringxbeam,ybeam andzbeam,shown in Fig.2,Fig.3 and Fig.5,we getτx∶τy∶τz=1∶1∶0.54. ThereforeRx∶Ry∶Rz=1∶1∶0.54 is concluded. This atomic cloud is about the geometric three-dimensional shape. Tri-axial ellipsoid with distinct semi-axis lengthsRx,Ry,andRz. An ellipsoid is a closed quadric surface that is a three-dimensional analogue of an ellipse. The standard equation of an ellipsoid centered at the origin of a Cartesian coordinate system and aligned with the axes is

      (3)

      The points (Rx,0,0),(0,Ry,0) and (0,0,Rz) lie on the surface and the line segments from the origin to these points are called the semi-principal axes of lengthRx,Ry,andRz.

      Fig.5 MOT photodiode voluage (fluorescence) during trap loading by shuttering the trapping light ofZ

      (a):Fluorescence signal collected by oscilloscope; (b):Loading procedure. A 2.04 s loading 1/etime was used.

      They correspond to the semi*major axis and semi-minor axis of the appropriate ellipses. Here,Rx,Ry,Rzare the radius of the atoms cloud along thex,y,zaxes. Finally semi-axis lengthsRx=1.06 mm,Ry=1.06 mm,Rz=0.57 mmwere got,and the three-dimensional image of cold atomic cloud was simulated,shown in Fig.6.

      Conclusion

      In this paper,we have realized simulating of the three-dimensional image of cold atomic cloud. Compared to former two-dimensional image by probe laser,the three-dimensional image of cold atomic cloud is intuitive and stereoscopic. The number of trapped atoms is about 108. The atomic cloud is about the geometric three-dimensional shape. Tri-axial ellipsoid with distinct semi-axis lengthsRx=1.06 mm,Ry=1.06 mm,Rz=0.57.

      [1] Steven Chu、Nobel Lecture. Rev. Mod. Phys.,1998、70: 685.

      [2] Chu S,Hollberg L,Bjorkholm J E,et al. Phys. Rev. Lett.、1985、55(1):48.

      [3] Raab E L,Prentiss M,Cable A,et al. Phys. Rev. Lett.,1987,59: 2631.

      [4] Cohen-Tannoudji C N. Manipulating Atoms with Photons. Nobel Prize Lecture. 8th December、1997.

      [5] Phillips W D. Rev. of Mod. Phys.,1998,70: 721.

      [6] Andrejs Vorozcovs,Matthew Weel,Scott Beattie,et al. J. Opt. Soc. Am. B,2005,22(5): 943.

      [7] Colin Cameron A,Frank A G Windmeijer. Journal of Econometrics,1997,77(2): 329.

      [8] Steck D A. Rubidium 87 D Line Data. Los Alamos National Laboratory,2001.

      O562.3

      A

      冷原子的三維圖像模擬

      彭 瑜1,2

      1. 北京林業(yè)大學(xué)理學(xué)院,北京 100083 2. 清華大學(xué)量子信息中心,北京 100084

      提出了一種用于精確模擬冷原子云的三維圖像方案、這個方案比先前通過探測激光的方法所獲得的二維圖像更加直觀和立體。該研究實現(xiàn)了冷原子云的模擬、捕獲原子的數(shù)量約為108。原子云是幾何三維形狀、Rx=1.06 mm,Ry=1.06 mm,Rz=0.57 mm,具有不同半軸長度的三軸橢圓體。

      原子光學(xué); 激光冷卻、激光

      2016-03-15、

      2016-07-22)

      2016-03-15; accepted:2016-07-22

      National Natural Science Foundation of China (11504022),Fundamental Research Funds for the Central Universities (BLX2015-09),and National Natural Science Foundation of China(31530084)

      10.3964/j.issn.1000-0593(2016)12-4130-05

      Biography:PENG Yu,(1980—),Ph. D.,in Beijing Forestry University e-mail: pengyu@bjfu.edu.cn

      猜你喜歡
      三軸北京林業(yè)大學(xué)半軸
      歡迎訂閱2023年《北京林業(yè)大學(xué)學(xué)報(社會科學(xué)版)》
      《北京林業(yè)大學(xué)學(xué)報(社會科學(xué)版)》2022年總目次
      法蘭盤半軸鉆鉸錐孔專用夾具設(shè)計
      基于自適應(yīng)參數(shù)估計的三軸磁傳感器實時校正方法
      How to Understand the Story of an Hour Using Id, Ego and Superego
      Pilot Study for The Relationship Between Politeness and Prosodic Features
      汽車半軸用鋼電沉積Ni-SiC復(fù)合鍍層的耐磨性
      基于嵌入式Soft-PLC 的三軸數(shù)控系統(tǒng)設(shè)計
      基于鋁擠壓模具倒扣型面的三軸加工應(yīng)用
      某重型車橋半軸斷裂失效分析
      大田县| 遵义县| 安乡县| 伊金霍洛旗| 和田市| 阿拉善左旗| 石阡县| 天峨县| 西林县| 南部县| 正蓝旗| 望江县| 天津市| 普兰县| 乌兰县| 崇左市| 兴化市| 利川市| 龙岩市| 凤庆县| 怀远县| 白河县| 乐安县| 临朐县| 成武县| 揭西县| 武隆县| 眉山市| 西畴县| 静海县| 洪洞县| 岢岚县| 革吉县| 自治县| 平阳县| 陈巴尔虎旗| 类乌齐县| 汝阳县| 商都县| 乐清市| 方山县|