甄偉勁
[摘? ? 要]社會(huì)經(jīng)濟(jì)的發(fā)展對(duì)于供電服務(wù)提出了全新的要求,多元化的供電服務(wù)需求需要供電企業(yè)不斷地提高供電服務(wù)水平,確保供電可靠性,然而,供電可靠性的提高更需要精細(xì)化的管理模式。文章首先分析了配網(wǎng)系統(tǒng)供電可靠性管理現(xiàn)狀,然后重點(diǎn)探討了配網(wǎng)供電可靠性精細(xì)化管理的對(duì)策。
[關(guān)鍵詞]配網(wǎng)供電可靠性;現(xiàn)狀;精細(xì)化管理;對(duì)策
[中圖分類號(hào)]TM711 [文獻(xiàn)標(biāo)志碼]A [文章編號(hào)]2095–6487(2021)01–0–03
Research on Reliability Reliability Management of Distribution Network
Zhen Wei-jin
[Abstract]Economic and social development has put forward new requirements for power supply services. Diversified power supply service needs require power supply companies to continuously improve power supply service levels to ensure power supply reliability. However, the improvement of power supply reliability requires more refined management mode. This article first analyzes the current situation of power supply reliability management of distribution network system, and then focuses on the countermeasures of fine management of power supply reliability of distribution network.
[Keywords]distribution network power supply reliability; status quo; refined management; countermeasures
近年來(lái),配網(wǎng)供電可靠性的研究逐漸增加,精細(xì)化管理模式取得了十分明顯的效果,通過(guò)加強(qiáng)配網(wǎng)精細(xì)化管理能夠提高供電服務(wù)效率,減少配網(wǎng)供電服務(wù)中的斷電現(xiàn)象,縮小停電范圍,減少客戶停電次數(shù),從而提高供電服務(wù)水平。
1 配網(wǎng)供電可靠性管理現(xiàn)狀分析
1.1 電網(wǎng)規(guī)劃不合理
配網(wǎng)規(guī)劃不合理體現(xiàn)在:網(wǎng)架結(jié)構(gòu)薄弱,線路無(wú)法達(dá)到N-1校驗(yàn)標(biāo)準(zhǔn),線路的不合理分段,停電狀態(tài)下無(wú)法及時(shí)檢修。配網(wǎng)沒有根據(jù)設(shè)備投運(yùn)年限來(lái)做出診斷,老舊設(shè)備未能動(dòng)態(tài)更新,進(jìn)而釀成事故頻發(fā),同時(shí),未能立足長(zhǎng)遠(yuǎn)預(yù)測(cè)項(xiàng)目用電需求,導(dǎo)致系統(tǒng)重復(fù)改造,出現(xiàn)反復(fù)停電問(wèn)題。
1.2 停電計(jì)劃管理不嚴(yán)
供電企業(yè)忽視了停電計(jì)劃的合理制定,導(dǎo)致停電戶數(shù)、時(shí)長(zhǎng)等都超出了合理的標(biāo)準(zhǔn)和范圍,未能周密分析停電方案,使得停電范圍不斷地?cái)U(kuò)大,施工人員、力量等未能做出合理地安排,施工人員自身的技術(shù)水平、素質(zhì)等也不相同,從而使得檢修中停電時(shí)間難以保證。
1.3 故障停電比重大
由于配網(wǎng)系統(tǒng)的線路、設(shè)備等的檢修、維護(hù)等不及時(shí)、不到位,從而導(dǎo)致配網(wǎng)系統(tǒng)故障停電的情況經(jīng)常出現(xiàn),配網(wǎng)系統(tǒng)中設(shè)備質(zhì)量低下,設(shè)備的參數(shù)、型號(hào)等的配置不合理等也加劇了故障問(wèn)題,搶修人員的素質(zhì)、能力和水平等都將影響到配網(wǎng)系統(tǒng)故障的搶修,進(jìn)而影響到配網(wǎng)供電的可靠性、安全性;同時(shí),因?yàn)槿鄙俦匾陌踩雷o(hù)與隔斷措施,使得個(gè)別用戶設(shè)備出現(xiàn)故障時(shí)導(dǎo)致整個(gè)系統(tǒng)處于斷電狀態(tài),影響其他用戶的正常用電。
1.4 轉(zhuǎn)供電管理力度不夠
配網(wǎng)系統(tǒng)出現(xiàn)故障或局部需要檢修時(shí),可以采用轉(zhuǎn)供電模式來(lái)減少停電范圍,然而,現(xiàn)實(shí)的配網(wǎng)系統(tǒng)供電可靠性管理中,往往忽視了轉(zhuǎn)供電技術(shù)的運(yùn)用,在未實(shí)行轉(zhuǎn)供電的情況下就直接進(jìn)行線路檢修或者斷電,這樣無(wú)疑擴(kuò)大了停電范圍,影響供電的安全性和可靠性。同時(shí),供電企業(yè)缺少先進(jìn)的智能化監(jiān)測(cè)系統(tǒng),無(wú)法動(dòng)態(tài)監(jiān)測(cè)供電系統(tǒng)的運(yùn)行狀態(tài),對(duì)于一些設(shè)備、線路等無(wú)法實(shí)施動(dòng)態(tài)監(jiān)管,從而影響轉(zhuǎn)供電能力。
2 配網(wǎng)供電可靠性的精細(xì)化管理對(duì)策
2.1 嚴(yán)格配網(wǎng)規(guī)劃,完善網(wǎng)架結(jié)構(gòu)
2.1.1 科學(xué)編制配網(wǎng)規(guī)劃
要全面、綜合地衡量一個(gè)低于的功能定位、經(jīng)濟(jì)發(fā)展水平從而綜合評(píng)估該地區(qū)未來(lái)的用電量潛在需求,具體可以把配網(wǎng)規(guī)劃列入城鎮(zhèn)總體規(guī)劃工作中,制定控制性規(guī)劃目標(biāo),以此來(lái)實(shí)現(xiàn)配網(wǎng)規(guī)劃與城市的未來(lái)發(fā)展、規(guī)劃建設(shè)等密切配合,可以適當(dāng)?shù)厍耙脐P(guān)口,將供電可靠性作為配網(wǎng)規(guī)劃水平的一大衡量標(biāo)準(zhǔn),實(shí)行“一個(gè)市區(qū)一個(gè)規(guī)劃方案”“一座城鎮(zhèn)一冊(cè)規(guī)劃方案”的制度,實(shí)施規(guī)劃方案修編制度,以此來(lái)提升供電可靠性,創(chuàng)建科學(xué)、完善的網(wǎng)架結(jié)構(gòu),以此來(lái)提高配網(wǎng)供電可靠性。
2.1.2 完善網(wǎng)架結(jié)構(gòu)
健全完善的網(wǎng)架結(jié)構(gòu)是保證供電安全性、可靠性的前提和基礎(chǔ),根據(jù)典型接線模式,來(lái)對(duì)線路進(jìn)行分段、聯(lián)絡(luò),實(shí)施環(huán)網(wǎng)供電模式,而且要實(shí)行互相備用的網(wǎng)架結(jié)構(gòu),從而全面提高線路環(huán)網(wǎng)率與轉(zhuǎn)供電能力,既要達(dá)到N-1的要求,也要對(duì)一些VIP客戶實(shí)施N-2模式,同時(shí),要達(dá)到科學(xué)的變壓器容載比要求,通過(guò)這種方式來(lái)控制電源點(diǎn)分布不足,線路卡滯與過(guò)載等弊端,優(yōu)化容載比,確保電網(wǎng)結(jié)構(gòu)科學(xué)、配網(wǎng)系統(tǒng)能夠高效靈活運(yùn)轉(zhuǎn),提高設(shè)備的安全性。
2.1.3 優(yōu)化配網(wǎng)結(jié)構(gòu)設(shè)計(jì)
配網(wǎng)是配網(wǎng)系統(tǒng)中較為薄弱、基礎(chǔ)的部分,如果配網(wǎng)結(jié)構(gòu)設(shè)計(jì)不合理則將影響配網(wǎng)系統(tǒng)規(guī)劃,也將難以達(dá)到分區(qū)域、分層次供電的目標(biāo),不能實(shí)現(xiàn)負(fù)荷中心各個(gè)級(jí)別支撐電源的需求。所以,本著電網(wǎng)規(guī)劃的原則和思路來(lái)采用分區(qū)域、逐領(lǐng)域提供電能,要嚴(yán)格控制配電網(wǎng)的交叉重合現(xiàn)象,要達(dá)到科學(xué)地電源布點(diǎn),以此來(lái)解除線路與設(shè)備的過(guò)載荷問(wèn)題。
2.2 設(shè)備運(yùn)行精細(xì)化管理,降低設(shè)備故障率
精細(xì)化管理要從多方面出發(fā)、立足于多角度,從各個(gè)環(huán)節(jié)入手實(shí)行精細(xì)化管控,具體可以從線路、設(shè)備、工程等方面入手來(lái)加強(qiáng)管理,具體體現(xiàn)在:
2.2.1 重視線路與設(shè)備的運(yùn)行與維護(hù)
參照《配網(wǎng)系統(tǒng)運(yùn)行規(guī)程》中的規(guī)程、規(guī)定與條例,要加強(qiáng)日常的系統(tǒng)運(yùn)行、維護(hù)與檢修,對(duì)配網(wǎng)線路來(lái)說(shuō)需要做好配網(wǎng)線路的紅外測(cè)溫,強(qiáng)化電纜的局部放電測(cè)試,通過(guò)技術(shù)性的監(jiān)督、檢查與測(cè)試來(lái)明確其中的技術(shù)問(wèn)題,同時(shí),對(duì)線路附近環(huán)境的整頓與清理,例如:清理樹木障礙物,為線路的架設(shè)與延伸提供暢通的通道,而且要積極地補(bǔ)齊電纜標(biāo)識(shí)物,密切關(guān)注四周的工程施工情況,提醒施工單位附近的電纜、線路等的敷設(shè)情況,掌握好施工工程與線路之間的安全距離。
2.2.2 做好設(shè)備質(zhì)量檢查
配網(wǎng)系統(tǒng)中電氣設(shè)備質(zhì)量直接關(guān)系到整個(gè)配網(wǎng)供電可靠性,所以必須嚴(yán)格配網(wǎng)系統(tǒng)設(shè)備的質(zhì)量檢查,控制因?yàn)樵O(shè)備質(zhì)量低下導(dǎo)致的系統(tǒng)故障,具體可以通過(guò)設(shè)備抽檢的方式來(lái)發(fā)現(xiàn)其中的劣等設(shè)備,不達(dá)標(biāo)的劣質(zhì)設(shè)備堅(jiān)決不允許投入運(yùn)行。要精準(zhǔn)地記下各種設(shè)備的參數(shù)、型號(hào),為日后的產(chǎn)品批次調(diào)查與問(wèn)題規(guī)避創(chuàng)造有利條件,而且要?jiǎng)討B(tài)地更新設(shè)備。
2.2.3 工程質(zhì)量驗(yàn)收,確保施工工藝水平
配網(wǎng)系統(tǒng)工程建設(shè)完成后必須做好工程質(zhì)量驗(yàn)收與檢查,要由專業(yè)的驗(yàn)收人員按照規(guī)定的流程對(duì)工程進(jìn)行嚴(yán)格的細(xì)致驗(yàn)收,保證各個(gè)環(huán)節(jié)、各個(gè)部位的施工都達(dá)到了規(guī)定的標(biāo)準(zhǔn),以此來(lái)確保配網(wǎng)工程的工藝水平,保證工程質(zhì)量。
2.2.4 重視客戶專用設(shè)備的安全監(jiān)管
一些重要客戶的專用設(shè)備也必須實(shí)施安全監(jiān)管,因?yàn)閭€(gè)別客戶自身設(shè)備發(fā)生故障時(shí)將對(duì)整個(gè)配網(wǎng)系統(tǒng)的正常供電帶來(lái)影響,可以為客戶裝設(shè)“看門狗”,當(dāng)客戶自身設(shè)備出現(xiàn)故障時(shí)能自行地阻斷故障,控制故障的蔓延,限制故障在客戶自家范圍內(nèi),以此來(lái)提高供電可靠性。
2.3 穩(wěn)步推動(dòng)帶電作業(yè)
大量的配網(wǎng)系統(tǒng)運(yùn)維工作實(shí)踐證實(shí):帶電作業(yè)是確保供電可靠性的有效舉措,因?yàn)榕渚W(wǎng)帶電作業(yè)不僅能控制重復(fù)停電現(xiàn)象,也能控制停電次數(shù)與時(shí)間,這樣就維持了配網(wǎng)系統(tǒng)的持續(xù)供電。
2.3.1 嚴(yán)格停電作業(yè)審批
為了積極推進(jìn)帶電作業(yè),要對(duì)停電作業(yè)項(xiàng)目進(jìn)行嚴(yán)格審批,只有特殊的無(wú)法實(shí)施帶電作業(yè)的地域或項(xiàng)目經(jīng)過(guò)多重審批才能真正進(jìn)入停電作業(yè)程序。在一切允許的條件或區(qū)域都要實(shí)施帶電作業(yè),而且要?jiǎng)?chuàng)建專門的帶電作業(yè)班組,購(gòu)置帶電作業(yè)車輛與設(shè)備、工具等,而且要積極地組織作業(yè)班組參與帶電作業(yè)的培訓(xùn),當(dāng)所有人都取得了帶電作業(yè)的資格后才能上崗。
2.3.2 完善帶電作業(yè)安全管理機(jī)制
必須積極地健全帶電作業(yè)管理制度,而且要編制出配網(wǎng)帶電作業(yè)的安全管理規(guī)程、現(xiàn)場(chǎng)操作規(guī)程與常規(guī)項(xiàng)目作業(yè)規(guī)程等,每次帶電作業(yè)前都要對(duì)系統(tǒng)的潮濕度、風(fēng)向等進(jìn)行檢查,校驗(yàn)作業(yè)工具、設(shè)備等,實(shí)施安全交底,由專業(yè)人員對(duì)作業(yè)現(xiàn)場(chǎng)實(shí)施檢查、監(jiān)督,排除一切帶電作業(yè)的風(fēng)險(xiǎn)因素。
2.3.3 掌握帶電作業(yè)技術(shù)
要充分地利用已掌握的帶電作業(yè)技術(shù)與經(jīng)驗(yàn),對(duì)于一些關(guān)鍵環(huán)節(jié),例如:配網(wǎng)基建、線路設(shè)備故障控制等項(xiàng)目都要扎實(shí)地實(shí)施帶電作業(yè),這其中最關(guān)鍵是要掌握帶電作業(yè)技術(shù),特別是一些危險(xiǎn)作業(yè)環(huán)節(jié),例如:架空線路拆接火、柱上開關(guān)的更換、絕緣子更換、避雷器的安裝等,而且要正確地處理線夾與導(dǎo)線斷裂等問(wèn)題,做好一切常規(guī)作業(yè),例如:帶電立桿、線路漂掛物的清理等。
2.4 引進(jìn)帶電作業(yè)新技術(shù),提高自動(dòng)化水平
2.4.1 提高配網(wǎng)自動(dòng)化水平
供電企業(yè)必須加大配網(wǎng)自動(dòng)化建設(shè)速度,全面提升配網(wǎng)運(yùn)行的動(dòng)態(tài)監(jiān)控水平,大力投入配網(wǎng)自動(dòng)化設(shè)備,而且要對(duì)設(shè)備進(jìn)行自動(dòng)遙控,實(shí)現(xiàn)對(duì)故障的遠(yuǎn)距離隔離,實(shí)施不停電合環(huán)轉(zhuǎn)供電操作,以此來(lái)回歸非故障區(qū)域的電力供應(yīng)。以此來(lái)減少運(yùn)維人員現(xiàn)場(chǎng)運(yùn)維的時(shí)間與次數(shù),達(dá)到線路故障的高效、及時(shí)定位,將故障能及時(shí)地隔離,減少故障定位與查找時(shí)間。
2.4.2 加快配網(wǎng)狀態(tài)監(jiān)測(cè)技術(shù)的應(yīng)用
要大力推進(jìn)配網(wǎng)狀態(tài)監(jiān)測(cè)技術(shù)的應(yīng)用,發(fā)揮其自動(dòng)化監(jiān)測(cè)優(yōu)勢(shì)。例如:對(duì)開關(guān)柜、環(huán)網(wǎng)柜、電纜分接箱等的局放測(cè)試,連接位置的紅外測(cè)試、電纜震蕩波測(cè)試等,以此來(lái)動(dòng)態(tài)掌握各類設(shè)備的運(yùn)行模式、工作狀態(tài),為檢修方案的制定提供參考。狀態(tài)監(jiān)測(cè)技術(shù)的運(yùn)用能夠控制檢修的無(wú)目的性,提高配網(wǎng)系統(tǒng)檢修效率,從而控制檢修成本,控制停電檢修對(duì)供電可靠性帶來(lái)的威脅。
2.4.3 全面提升配網(wǎng)線路防雷水平
做好配網(wǎng)系統(tǒng)線路與設(shè)備的防雷保護(hù),要集中加強(qiáng)對(duì)線路、接地設(shè)備等的防雷改造與優(yōu)化,可以將防護(hù)金具、避雷器等安裝在雷害重災(zāi)區(qū),此次來(lái)防止因?yàn)槔缀υ斐傻木€路中斷問(wèn)題,控制線路故障發(fā)生率,進(jìn)而提高供電可靠性。
2.5 轉(zhuǎn)供電的精細(xì)化管理
2.5.1 實(shí)施停電必轉(zhuǎn)制度
現(xiàn)實(shí)的停電計(jì)劃統(tǒng)籌工作中,對(duì)于能達(dá)到轉(zhuǎn)供電條件的區(qū)域必須提前做出安排,本著“停電必轉(zhuǎn)、能轉(zhuǎn)必轉(zhuǎn)”的思路來(lái)開展轉(zhuǎn)供電,一些因?yàn)橄到y(tǒng)故障出現(xiàn)停電的情況則要本著“先轉(zhuǎn)再修”的思路,也就是要先將故障點(diǎn)隔開然后通過(guò)轉(zhuǎn)供電的方式維持故障區(qū)域的正常供電,以此來(lái)控制非故障區(qū)域的停電現(xiàn)象。
2.5.2 強(qiáng)化轉(zhuǎn)供電的全局統(tǒng)籌
調(diào)度中心負(fù)責(zé)轉(zhuǎn)供電的統(tǒng)籌與全局化管理,一切配網(wǎng)停電計(jì)劃、規(guī)劃中可以進(jìn)行轉(zhuǎn)供電的,都必須預(yù)先編制轉(zhuǎn)供電的方案,加強(qiáng)轉(zhuǎn)供電的全過(guò)程、全方位管控,而且要積極地統(tǒng)計(jì)、分析各個(gè)月份的轉(zhuǎn)供電工作落實(shí)情況,對(duì)轉(zhuǎn)供電工作情況實(shí)施量化考核、定期公開,以此來(lái)形成對(duì)轉(zhuǎn)供電的監(jiān)督。
2.5.3 提高轉(zhuǎn)供電操作效率
科學(xué)地編制配網(wǎng)設(shè)備倒閘操作的時(shí)間指標(biāo),并要指明各類設(shè)備、相關(guān)裝置的轉(zhuǎn)供電操作時(shí)長(zhǎng),特別在安排與多點(diǎn)轉(zhuǎn)供電操作相關(guān)的任務(wù)時(shí),各組操作人員之間必須積極配合,而且預(yù)先做好一切操作準(zhǔn)備再抵達(dá)操作現(xiàn)象,控制轉(zhuǎn)供電的操作時(shí)間。
2.5.4 積極推進(jìn)合環(huán)轉(zhuǎn)電
現(xiàn)實(shí)證實(shí),線路轉(zhuǎn)供電在眾多的控制停電次數(shù)、縮小停電范圍的措施中最為有效、最為科學(xué)。而且配網(wǎng)不停電轉(zhuǎn)供電能夠妥善地保證對(duì)客戶的安全、平穩(wěn)、可持續(xù)供電,能夠提高客戶對(duì)供電服務(wù)的滿意度。通過(guò)合環(huán)轉(zhuǎn)供電能夠削減停電通知客戶的繁瑣環(huán)節(jié),客觀上就提高了供電服務(wù)效率。所以,必須做好合環(huán)轉(zhuǎn)電的管理,例如:規(guī)范聯(lián)絡(luò)圖繪制與合環(huán)點(diǎn)的對(duì)相等,對(duì)于一切達(dá)到合環(huán)轉(zhuǎn)電標(biāo)準(zhǔn)的線路都要采用合環(huán)轉(zhuǎn)電模式。
3 結(jié)束語(yǔ)
配網(wǎng)系統(tǒng)供電可靠性直接影響到客戶的供電服務(wù)水平,關(guān)系到客戶對(duì)供電服務(wù)的滿意度,所以,必須做好配網(wǎng)供電可靠性的精細(xì)化管理,通過(guò)精細(xì)化的管理來(lái)深化停電控制,減少故障停電次數(shù),縮小停電范圍,以此來(lái)提高供電可靠性。
參考文獻(xiàn)
[1] 郭永基.電力系統(tǒng)可靠性分析[M].北京:清華大學(xué)出版社,2003.
[2] 溫德誠(chéng).精細(xì)化管理[M].北京:新華出版社,2005.
[3] 楊武蓋.配電網(wǎng)及其自動(dòng)化[M].北京:中國(guó)水利水電出版社,2004.
[4] 代曉豐.廣州地區(qū)供電系統(tǒng)供電可靠性對(duì)標(biāo)與改進(jìn)策略研究[D].廣州:華南理工大學(xué),2013.